• -3%
  • New
CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display
search
  • CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display
  • CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display
  • CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display
  • CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display
  • CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display

CAFF Relay Protector 3-Phase 4-Wire 100A VA Monitor 380V (L-L) Display

Rp790,000
Rp766,300 Save 3%
Tax excluded
Quantity

SKU: 12024661931
  Security policy

We protect your personal information with appropriate security measures to prevent unauthorized access, misuse, or disclosure.

  Delivery policy

Orders are processed and shipped as quickly as possible. Delivery times may vary depending on destination, courier service, and product availability.

  Return policy

If you receive a damaged, defective, or incorrect item, please contact us promptly. Returns or exchanges are subject to the applicable terms and time limits.

##################################
READY STOCK, SILAHKAN LANGSUNG ORDER
##################################

CAFF

3-PHASE VOLTAGE, CURRENT, UNBALANCE, PHASE LOSS PROTECTOR

VOLTAGE DISPLAY : 3x380V (L-L Voltage)
MAX CURRENT : 100A

Function:
1. Under voltage protection (adjustable)
2. Over voltage protection (adjustable)
3. Over current protection (adjustable)
4. Voltage balance protection (adjustable)
5. Phase Loss protection
6. Active time and reconnect time (adjustable)
7. Voltmeter
8. Ammeter

PRODUCT PARAMETERS:
Brand : CAFF
Model number: BDOVP4-100VA
Rated Input Voltage (L-L Voltage) : 380VAC 50/60Hz
Operating Voltage (L-L Voltage) : 240-520VAC 50/60Hz
Power-ON Delay time: 1-500s (default: 10s)
Over-voltage protection value (L-L Voltage) : 395V~520V (default:460V)
Over-voltage recovery value (L-L Voltage) : 390V~515V (default:455V)
Under-voltage protection value (L-L Voltage) : 240V~365V (default: 300V)
Under-voltage recovery value (L-L Voltage) : 245V~370V (default: 305V)
Three phase voltage error value : -9.5% ~ 9.5% (default: 0)
Three phase voltage unbalance value : 20V~99V (default:40V)
Three phase voltage unbalance recovery value : 15V~94V (default:35V)
Three phase voltage unbalance protection switch : OFF/ON (default: OFF)
Over-Current protection value (L1, L2, L3) : 1-100A (default 60A)
Recovery delay time : 1-500s (default : 30s) Action time : 0.1-30s (default : 1s)
Continuous over current faults times : 1-20 times (default: OFF)
Phase-loss protection : ON
Electrical & Mechanical life : > 100000 cycles
Dimension : 91 x 90 x 66mm
Wiring :
--- INPUT : BOTTOM side
--- OUTPUT : UPPER side